IECC climate-zone target R-value by assembly

Typical published planning values — NOT a certified design. Real performance depends on installation quality, framing / thermal bridging, moisture and settling; follow the product data sheet and your local energy code. Foam ignition/thermal-barrier, vapor/moisture control and combustion-air safety are set by the manufacturer and code — check with a professional.

The IECC and ENERGY STAR publish recommended R-values by climate zone and assembly. The table below is labeled planning typicals — attic, wall-cavity and floor targets by zone 1–8. Confirm the current recommendation and your local energy code. Use it with the climate-zone target-R reference and the attic R by climate zone.

IECC zoneAtticWall cavityFloor
Zone 1R30–R49R13–R15R13–R13
Zone 2R38–R49R13–R15R13–R13
Zone 3R38–R49R13–R15R19–R19
Zone 4R49–R60R13–R21R19–R30
Zone 5R49–R60R13–R21R25–R30
Zone 6R49–R60R19–R21R25–R30
Zone 7R49–R60R19–R21R25–R30
Zone 8R49–R60R19–R21R25–R30

Labeled IECC/ENERGY STAR planning typicals — confirm the current recommendation and your local energy code. Colder zones (higher numbers) call for more R; a wall band can also be met as R-13 cavity + continuous exterior foam.